Environmental Data Coding Specifcation        ISO IEC LogosRight Title Graphic
Home Browse Search Download Submissions FAQs Contact
 

EA:  ATM_PRESSURE_CHANGE_TENDENCY_CATEGORY

Status: STD 2005/06/07
Code: 121

Concept definition: The qualitative <<ATM_PRESSURE_CHANGE_3_HOUR>>; atmospheric pressure change tendency category.
 
Attribute value type: ENUMERATION
Reference type: IR
Reference: [WMO306, Volume 2, Code table 0-10-063]
Supplemental references:  

Enumerants (presented in a natural order)
Status Attribute label Enumerant label ▾ Concept definition Code Ref type Reference Supplemental references
STD
2005/06/07
ATM_PRESSURE_CHANGE-
_TENDENCY_CATEGORY
CHANGE_TO_DEC Steady or increasing, then decreasing; or decreasing, then decreasing more rapidly; with <<ATM_PRESSURE>> lower than 3 hours earlier. 9 PR [WMO306, Volume 2, Code table 0-10-063:8]  
STD
2005/06/07
ATM_PRESSURE_CHANGE-
_TENDENCY_CATEGORY
CHANGE_TO_INC Decreasing or steady, then increasing; or increasing then increasing more rapidly; with <<ATM_PRESSURE>> higher than 3 hours earlier. 4 PR [WMO306, Volume 2, Code table 0-10-063:3]  
STD
2005/06/07
ATM_PRESSURE_CHANGE-
_TENDENCY_CATEGORY
DEC_PRESSURE_LESS Steadily or unsteadily decreasing with <<ATM_PRESSURE>> lower than 3 hours earlier. 8 PR [WMO306, Volume 2, Code table 0-10-063:7]  
STD
2005/06/07
ATM_PRESSURE_CHANGE-
_TENDENCY_CATEGORY
DEC_THEN_INC Decreasing then increasing with <<ATM_PRESSURE>> the same or lower than 3 hours earlier. 6 PR [WMO306, Volume 2, Code table 0-10-063:5]  
STD
2005/06/07
ATM_PRESSURE_CHANGE-
_TENDENCY_CATEGORY
DEC_THEN_STEADY Decreasing then steady; or decreasing then decreasing more slowly; with <<ATM_PRESSURE>> lower than 3 hours earlier. 7 PR [WMO306, Volume 2, Code table 0-10-063:6]  
STD
2005/06/07
ATM_PRESSURE_CHANGE-
_TENDENCY_CATEGORY
INC_PRESSURE_HIGHER Steadily or unsteadily increasing with <<ATM_PRESSURE>> higher than 3 hours earlier. 3 PR [WMO306, Volume 2, Code table 0-10-063:2]  
STD
2005/06/07
ATM_PRESSURE_CHANGE-
_TENDENCY_CATEGORY
INC_THEN_DEC Increasing then decreasing with <<ATM_PRESSURE>> the same or higher than 3 hours earlier. 1 PR [WMO306, Volume 2, Code table 0-10-063:0]  
STD
2005/06/07
ATM_PRESSURE_CHANGE-
_TENDENCY_CATEGORY
INC_THEN_STEADY Increasing then steady; or increasing then increasing more slowly; with <<ATM_PRESSURE>> higher than 3 hours earlier. 2 PR [WMO306, Volume 2, Code table 0-10-063:1]  
STD
2005/06/07
ATM_PRESSURE_CHANGE-
_TENDENCY_CATEGORY
STEADY_PRESSURE_EQUAL Steady with <<ATM_PRESSURE>> the same as 3 hours earlier; steady pressure equal. 5 PR [WMO306, Volume 2, Code table 0-10-063:4]  

Group membership:

In addition to the status and date information for each entry, a colour coding scheme highlights the database holding to which an entry belongs. The following highlight colours are used:

  • white - the entry is in the standard
  • yellow - the entry has been added to the register
  • pink - the entry has been submitted for inclusion in the register, but it is not approved
  • cyan - a deprecated entry that was originally either in the standard or was added to the register, but has since been deprecated

The following icons are used to identify items that have figures, modifications and/or clarification notes:

  • F n - has Figures and, if more than one figure, n figures
  • M - has Modifications
  • C - has Clarifications

Bottom Bar Graphic